 MC2 "Z" WITHOUT SENSORS

When using the MC2 without a sensor, select "Z" for the sensor option.  Sometimes it is not necessary to use sensors or it may be required to remotely locate sensors.  In the later, the MPS-V6 or MPS-V8 can be remotely located; closer to the pick up point to maximize the response and accuracy of the "part on - part off" vacuum point.  The programmable MPS-7 Series display can precisely control the sensor npn or pnp outputs.  For remote sensing applications, the sensors must be ordered separately.

________________________________________________________

MC2 without sensor

 

 MC2 WITH "MPS-2" SENSORS

When using the MC2 with an MPS-V2 sensor, select "V2" for the sensor option.  The "V2" sensor has 2 npn or pnp outputs available for vacuum confirmation.  Typical response times for the outputs with an average circuit is less than 50 msec.  The output response time of this sensor is less  than 2.5 msec.

________________________________________________________

MC2 with MPS-2
MPS-2 Information

 

 MC2 WITH "MVS-201" SENSORS

When using the MC2 with the MVS-201 sensor, select "201" for the sensor option.  The "201" sensor has one output npn or pnp for vacuum confirmation and a control output that interfaces directly with the blow-off release pilot valve.  With programmable time control features and a special chip driver, the sensor automatically activates the blow-off release when the vacuum signal from the PLC is discontinued.  This eliminates, THE PREVIOUSLY REQUIRED, PLC output to activate the blow-off release.  This new technology reduces PLC output requirements by 50% and reduces installation to a simple 4 wire system by wiring the sensors only.  For the MC2, there are 2 modes of operation for various applications.  The output response of the sensor is less than 2.5 msec.

________________________________________________________

MC2 with MVS-201
MVS-201 Information

 

 MC2 WITH "MPS-6" SENSORS

When using the MC2 with the MPS -V6 sensor, select "V6" for the sensor option.  The "V6" sensor has one normally open and one normally closed npn or pnp output available for vacuum confirmation.  The MPS-6 sensor is a cost effective performer with an output response time less than 1 msec.. and a nice adjustable 270 degree output range.

________________________________________________________

MC2 with MPS-V6
MPS-V6 Information

 

MC2 MANIFOLD SERIES

When using the MC2 in a manifold configuration, select the "M" option and indicate the number of stations on the suffix.  The MC2 can be assembled into a , 2 to a maximum of 8 station, manifold system.  Each station is independent and performs consistently; regardless of the number of stations operating.  The manifold has a common inlet pressure port.

_______________________________________________________  

MC2 MANIFOLD

   

MC2 CLEAN ROOM SERIES

When using the MC2 in a clean room environment where the exhaust needs to be contained, select  the "C" option.  Here the silencer is removed for a barb connection to contain the exhaust to protect the environment.  Simply connect tubing to the barb connection to manage the exhaust.

________________________________________________________

MC2 CLEAN ROOM MANIFOLD

 

   