Hysteresis
Mode (HYS): This output mode programs the sensor to control the output
signals "NPN or PNP" with switch points
"H-1" (output 1) and "H-2" (output 2) on
the graph below. The switch points are adjustable by
touch panel and independent. The Hysteresis is a value
"h-1/h-2" to control the output signals below
the switch point "H-1/H-2". This is adjustable
on the sensor and mathematically defined as:
(switch point)
"H-1/H-2"
MINUS
(Hysteresis value) "h-1/h-2"
HYSTERESIS RANGE
Hysteresis
Mode
WINDOW
COMPARATOR DEFINITION
Window
Comparator Mode (CNP): This output mode programs the sensor to provide
an output signal "NPN/PNP" between switch points
"A" and "B" on the graph below. The switch
points "A-1/A-2" (low point) and "B-1/B-2" (high
point) are independent and adjustable on the sensor. The
window comparator mode is sometimes referred to as a
"High/Low" setting or a "Failure prediction
mode". The reference depends on the application and
pressure ranges.
Window
Comparator Mode