MPS-8 - SPECIFICATIONS

Specifications

Media

 Non-lubricated air, non-corrosive gases

Pressure Port

 M5F Flange

Operating Temperature

 32~122°F (0~50° C)

Storage Temperature

 14~140° F (-10~60° C)

Humidity

 35~85% RH

Electrical Connection

 Grommet open lead 

Power Supply

 10.8~30 VDC, ripple (P-P) 10% max., reverse voltage protection

Switch Output

 1 output, normally open, NPN or PNP open collector transistor

Linear Output

 Analog output 1~5VDC or Current output 4~20mA

Switch Point Setting

 2/3 trimmer

Hysteresis setting

 < 2% of F.S.

Response Time

 < 1ms

Repeatability

 < 0.2% F.S.

Thermal Error

 Max. ± 2% F.S. in temperature range 32~122° F (0-50° C)

General Protection

 IP 40

Current Consumption

 < 20mA

Spike Protection

 Vp-p 400v, 0.5ms surge protection

Dielectric Strength

 1000VAC, 1min.

Insulation Resistance

 > 100M ohms at 500VDC

Vibration Resistance

 10 to 55Hz, 1.5mm, XYZ, 2 hrs.

Shock Resistance

 100 G, XYZ

Material

 Body: Polycarbonate Pressure port: Aluminum

Mass

 1.8 oz. (4g)

Parker Hannifin Corporation
Pneumatic Division North America
8676 East M-89 Richland, MI 49083
Toll Free U.S.A.

Phone: 888-266-8221
      Fax: 888-266-8223
Local and International
Phone: 1-616-629-2530
Fax: 1-616-629-2514