MPS-9 SERIES - OUTPUT MODES

 

 

HYSTERESIS DEFINITION

 

Hysteresis Mode (HYS): This output mode programs the sensor to control the output signal "NPN/PNP" at switch point "H-1" on the graph below.  The switch point is adjustable by touch panel.   The Hysteresis is a value "h-1" to control the output signal below the switch point "H-1".  This is adjustable on the sensor and is mathematically defined as:

 

                                         (switch point)          "H-1"

                                               MINUS

                                        Hysteresis value      "h-1" 

                                                                HYSTERESIS RANGE

 

Hysteresis Output Mode

 

 

 

 

 

 

 

Parker Hannifin Corporation
Pneumatic Division North America
8676 East M-89 Richland, MI 49083
Toll Free U.S.A.

Phone: 888-266-8221
      Fax: 888-266-8223
Local and International
Phone: 1-616-629-2530
Fax: 1-616-629-2514
Email: assmith@parker.com