MPS-74 SERIES

         SENSOR PROGRAMMING - STEP 1

DEFINITION
A. Output Setting Normally Open or Closed:
The output can be set to turn "on or off" at the pressure switch point by the user. The output is NPN (Sinking Voltage) or PNP (Sourcing Voltage). Typically, the system PLC will dictate the need for NPN or PNP outputs and the system programmer determines the logic of the output setting N.C. or N.O.

B. Units of Measure and Remote Pressure Range Selection: Units of measure can be selected on the sensor display. Also, the pressure range of the remote sensor must correspond to the pressure range selected on the MPS-7 Series to display the appropriate pressure.

P1: Vacuum 0 to -30inHg Select -inHg, -mmHg, -bar, -PA by using arrow "Up" and "Down" keys. Press mode key to enter.
P2: Low Pressure 0 to 14.5PSI Select PSI, Kgf/cm², bar, PA by using arrow "Up" and "Down" keys. Press mode key to enter.
P3: Pressure 0 to 145PSI Select PSI, Kgf/cm², bar, PA by using arrow "Up" and "Down" keys. Press mode key to enter.
P4: Compound -14.7PSI to +72.5PSI Select -PSI, Kgf/cm², bar, PA by using arrow "Up" and "Down" keys. Press mode key to enter.
  SWITCH OUTPUT MODE GRAPHS

hysteresisnew.jpg (136668 bytes)

windowcomp.jpg (136953 bytes)

PROGRAMMING PROCEDURE

A. OUTPUT SETTING OPEN OR CLOSED 

Select output configuration N.O. or N.C. for each individual channel by pressing the mode key and arrow "UP" keys simultaneously. Change output configuration N.O. or N.C. by using arrow "UP" or "DOWN" keys. Press the mode key to enter and store information. Display will automatically default to the next channel. Repeat this procedure for the remaining channels.

B. UNITS OF MEASURE AND REMOTE PRESSURE RANGE SELECTION
Select the pressure scale for each individual channel by pressing the mode key two times ("2" displayed). Select the scale for the appropriate remote sensor. After selecting, display will automatically default to selecting the preferred unit of measure. Press "Arrow Up" or "Arrow Down" keys to select the unit of measure. Press mode key to enter and repeat the procedure for the remaining channels. Each channel is independent.

 Go to Step: 1 2 3  Next Step>

 
 
 